title: Changing The Verbosity Of Timebase Logging
description: All four Timebase products — Historian, Collector, Explorer, and Pulse — use the same logging system. Logs are written to a rolling daily file and to the console (or Windows service output). A live log viewer is also available inside each product's web interface. By default, only informational and higher-severity messages from Timebase itself are shown; third-party library output is limited to warnings and errors. When you need to diagnose a problem, you can increase the verbosity for specific components without touching anything else.
---

[Skip to content](https://docs.timebase.flow-software.com/knowledge-base/changing-the-verbosity-of-timebase-logging#main-content)

[More support](https://docs.timebase.flow-software.com/knowledge-base/kb-tickets/new?hsLang=en)

[![FlowEmailHeader](https://docs.timebase.flow-software.com/hs-fs/hubfs/FlowEmailHeader.png?width=120&height=33&name=FlowEmailHeader.png)](https://flow-software.com/)

Open main navigation

Close main navigation

- [More support](https://docs.timebase.flow-software.com/knowledge-base/kb-tickets/new)
- [Open a Support Ticket](https://docs.timebase.flow-software.com/knowledge-base/kb-tickets/new)

[Open a Support Ticket](https://docs.timebase.flow-software.com/knowledge-base/kb-tickets/new?hsLang=en)

 Search all Timebase documentation

- There are no suggestions because the search field is empty.

1. [Timebase Knowledge Base](https://docs.timebase.flow-software.com/knowledge-base?hsLang=en)
2. [Timebase Historian](https://docs.timebase.flow-software.com/knowledge-base/timebase-historian?hsLang=en)

# Changing The Verbosity Of Timebase Logging

## When you need to diagnose a problem, you can increase the verbosity for specific components without touching anything else.

#### Overview

All four Timebase products — Historian, Collector, Explorer, and Pulse — use the same logging system. Logs are written to a rolling daily file and to the console (or Windows service output). A live log viewer is also available inside each product's web interface. By default, only informational and higher-severity messages from Timebase itself are shown; third-party library output is limited to warnings and errors. When you need to diagnose a problem, you can increase the verbosity for specific components without touching anything else.

#### Where Logs Are Written

Each product writes to the same three destinations simultaneously:

| Destination | Details |
| --- | --- |
| **Rolling log file** | One file per day, kept for 7 days. Older files are deleted automatically. |
| **Console / service output** | Visible when running in a terminal, or in service console output. |
| **In-browser log viewer** | Live view inside each product's web interface. Shows the last 1,000 log entries from the current session only — not persisted. |

### Log file locations

| Product | Windows path | Docker path |
| --- | --- | --- |
| Historian | `C:\ProgramData\Flow Software\Timebase\Historian\Logs\` | `/logs/` |
| Collector | `C:\ProgramData\Flow Software\Timebase\Collector\Logs\` | `/logs/` |
| Explorer | `C:\ProgramData\Flow Software\Timebase\Explorer\Logs\` | `/logs/` |
| Pulse | `C:\ProgramData\Flow Software\Timebase\Pulse\Logs\` | `/logs/` |

Log filenames include the date, e.g. `20260503.txt`. The path can be changed by setting the `Logs` key in `settings.config` or via environment variable.

#### How to Change the Log Level

Each product reads its log level from a `settings.config` file. Edit the `Serilog` section directly — the change takes effect immediately without restarting the service.

### Settings file locations

| Product | Windows path |
| --- | --- |
| Historian | `C:\ProgramData\Flow Software\Timebase\Historian\Settings\settings.config` |
| Collector | `C:\ProgramData\Flow Software\Timebase\Collector\Settings\settings.config` |
| Explorer | `C:\ProgramData\Flow Software\Timebase\Explorer\Settings\settings.config` |
| Pulse | `C:\ProgramData\Flow Software\Timebase\Pulse\Settings\settings.config` |

Docker: `/settings/settings.config` (mapped from the product's settings volume)

### The Serilog section

The `Serilog` section in `settings.config` controls which messages are shown:

```
"Serilog": {  "MinimumLevel": {    "Default": "Warning",    "Override": {      "Timebase.Historian": "Information",      "Timebase.Dataset": "Information"    }  }}
```

- **`Default`** — the minimum level for everything not listed in `Override`. Keep this at `Warning` to suppress noise from ASP.NET Core and other libraries.
- **`Override`** — per-namespace level settings. The product's own namespace is listed here so its messages appear at `Information` by default.

### Available log levels

Levels in order from least to most severe:

| Level | When to use |
| --- | --- |
| `Verbose` | Maximum detail — individual data points, internal loop iterations. Very high volume. |
| `Debug` | Detailed data flow — chunk sizes, batch results, connection events. Use for active diagnosis. |
| `Information` | Normal operation milestones. This is the default for Timebase code. |
| `Warning` | Recoverable problems — connection retries, token refresh, buffer activation. |
| `Error` | Failures that need attention but did not stop the service. |
| `Fatal` / `Critical` | Startup failures that caused the service to exit. |

### Namespace overrides for each product

Use these namespace values in the `Override` section of `settings.config`:

| Product | Namespace | What it covers |
| --- | --- | --- |
| Historian | `Timebase.Historian` | Historian service, datasets, API |
| Historian | `Timebase.Dataset` | Individual dataset operations |
| Collector | `Timebase.Collector` | Collector service and all plugins (OPC UA, MQTT, SparkplugB, etc.) |
| Collector — OPC UA only | `Timebase.Collector.OPCUA` | OPC UA plugin exclusively |
| Collector — MQTT only | `Timebase.Collector.MQTT` | MQTT plugin exclusively |
| Collector — SparkplugB only | `Timebase.Collector.SparkplugB` | SparkplugB plugin exclusively |
| Explorer | `Timebase.Explorer` | Explorer service, proxy, historian client |
| Pulse | `Timebase.Pulse` | Pulse service, authentication, certificates |

To set a level for all Timebase code across every namespace at once, use the parent namespace:

```
"Override": {  "Timebase": "Debug"}
```

### Alternate methods

You can also change the log level without editing `settings.config`:

**Environment variable** (takes effect on next restart):

```
Serilog__MinimumLevel__Default=DebugSerilog__MinimumLevel__Override__Timebase.Historian=Debug
```

**Docker compose:**

```
environment:  - Serilog__MinimumLevel__Override__Timebase.Historian=Debug
```

**Command-line argument** (highest precedence, overrides everything):

```
--Serilog:MinimumLevel:Default=Debug
```

#### What Each Level Shows

### Historian

**Information (default)**

| Message | What it means |
| --- | --- |
| `Historian starting ...` | Service is starting |
| `Historian 'Auth' configured as {Url} for '{ClientId}'` | OAuth2 authentication is active |
| `Historian 'Auth' disabled` | Running without authentication |
| `Historian started` | Fully initialized, all datasets loaded |
| `Process listening on {Urls}` | API is accepting requests |
| `Historian tags: {Count}` | Daily diagnostic summary |
| `Historian size: {Size} GB` | Storage summary |
| `Historian space available: {Space} GB ({Percent}%)` | Disk space check |
| `Historian removed dataset {DatasetName}` | Dataset deleted |

**Warning**

| Message | What it means |
| --- | --- |
| `Historian dataset {Dataset} collector has timed out, entering "store forward" state` | Collector disconnected — data will buffer |
| `Historian dataset {Dataset} collector has lost communication` | Extended collector disconnect |
| `Dataset directory for {DatasetName} not found at {Path}` | Dataset directory missing on disk |

**Debug** — Data flow messages: HTTP request details, chunk dispatch timing.

---

### Collector

**Information (default)**

| Message | What it means |
| --- | --- |
| `Collector starting ...` | Service is starting |
| `Collector plugin {Plugin} starting ...` / `started` | Plugin lifecycle |
| `Collector started` | All plugins running |
| `OPCUA plugin successfully created session` | OPC UA connected |
| `OPCUA plugin subscription cycle finished in {Elapsed}ms, {Matched} nodes matched, {Subscribed} total subscribed` | Node browsing complete |
| `OPCUA plugin Subscription[{Index}] now monitoring {Count} nodes` | Active subscriptions |
| `Client {name} store and forward deactivated for dataset {Dataset}` | Historian reconnected, buffer drained |
| `Client {name} tag cache successfully populated for dataset {Dataset} with {Count} tags` | Tag cache ready |

**Warning**

| Message | What it means |
| --- | --- |
| `Collector is running, but 'Active' setting is set to false, data collection is paused` | Collection intentionally paused |
| `OPCUA plugin failed to create session: {Exception}` | OPC UA connection failed — retrying every 10 seconds |
| `OPCUA plugin failed to read DataType for node {NodeId}` | Node skipped — check OPC UA server |
| `OPCUA plugin keep alive status: {KeepAlive}` | Keep-alive issue detected |
| `Client {name} hub connection to {BaseAddress} has disconnected` | Lost connection to Historian |
| `Client {name} store and forward activated for dataset {Dataset}. Buffered {Buffer} points` | Historian unreachable — buffering data |
| `MQTT plugin connection to {Broker}:{Port} failed: {Reason}` | MQTT connection error |
| `SparkplugB plugin Data Received before birth` | SparkplugB sequence issue |

**Critical (plugin startup failures)**

| Message | What it means |
| --- | --- |
| `Collector plugin {Plugin} failed to start: {Exception}` | Plugin failed — check configuration |
| `Collector '{Setting}' is not configured` | Required setting is missing |

**Debug** — Chunk-level write detail: `sending chunk for dataset {Dataset}: {Chunk} points for {Tags} tags`, write timing, buffering rate.

**Verbose** — Individual data point trace: `buffered {Tag} value {Value}: Message {SequenceNumber}`. Very high volume — use only for a single tag.

---

### Explorer

**Information (default)**

| Message | What it means |
| --- | --- |
| `Explorer starting ...` | Service is starting |
| `Explorer initialized` | Configuration loaded |
| `Process listening on {Urls}` | UI is accepting requests |
| `Source proxy service configuration reloaded` | Historian proxy updated |
| `Client {name} hub reconnected to {BaseAddress}: {ConnectionId}` | Reconnected to Historian |

**Warning**

| Message | What it means |
| --- | --- |
| `Client {name} hub connection to {BaseAddress} has disconnected` | Lost connection to Historian |
| `Client {name} store and forward activated for dataset {Dataset}` | Historian unreachable |
| `Client {name} failed to send status data to {BaseAddress}` | Status update failed |

**Critical (startup failures)**

| Message | What it means |
| --- | --- |
| `Explorer 'Historians' is not configured` | No historian defined in config |
| `Explorer Historian[{Index}] 'Host' is not configured` | Historian host missing |
| `Explorer configuration could not be loaded` | Config file unreadable |

**Debug** — Historian client connection detail, SignalR reconnect events, HTTP proxy request/response timing.

---

### Pulse

**Information (default)**

| Message | What it means |
| --- | --- |
| `Pulse starting ...` | Service is starting |
| `Pulse created {Count} default clients in {Object}` | Default OAuth2 clients seeded |
| `Pulse started` | Ready to handle authentication requests |
| `Process listening on {Urls}` | Accepting requests |
| `Certificates generated certificate: {Subject}, expires {Expiry}` | TLS certificate created or renewed |
| `RootCA Root CA generated and saved: {Subject}, expires {Expiry}` | Root CA created |
| `RootCA installed Root CA to OS trust store: {Subject}` | Root CA trusted by OS |

**Warning**

| Message | What it means |
| --- | --- |
| `JWT Challenge triggered. Authentication scheme: {AuthScheme}, Error: {Error}` | A request failed authentication |
| `RootCA failed to install Root CA to OS trust store` | Manual trust store installation may be needed |
| `Skipping key due to missing private key material or ID` | A signing key is malformed |

**Error**

| Message | What it means |
| --- | --- |
| `JWT Authentication Failed` | Token validation failed — check client credentials and Pulse URL |
| `No signing keys found in storage. JWT validation will fail` | Key store is empty — restart Pulse to regenerate keys |
| `No validation keys provided by IKeyProvider` | Key provider returned nothing |

**Debug** — JWT validation detail per request, OAuth2 authorization code flow steps, configuration reload notifications.

#### Common Diagnostic Scenarios

### Collector not delivering data to Historian

1. Set `Timebase.Collector` to `Debug` in the Collector's `settings.config`.
2. Look for `sending chunk for dataset ...` — if absent, data is not reaching the write client.
3. Look for `store and forward activated` — this means the Historian is unreachable from the Collector.
4. Verify the Historian URL and port in the Collector configuration.

### Historian shows gaps in tag data

1. Check the Historian's log for `dataset {Dataset} collector has timed out` — this marks when the Collector disconnected.
2. Check the Collector's log for `hub connection to {BaseAddress} has disconnected` around the same time.
3. If Store and Forward was active, look for `store and forward deactivated` to confirm data was recovered on reconnection.

### OPC UA tags not appearing or not updating

1. Set `Timebase.Collector.OPCUA` to `Debug` in the Collector's `settings.config`.
2. Look for `subscription cycle finished in {Elapsed}ms, {Matched} nodes matched` — if `Matched` is 0, no configured tags matched any OPC UA nodes. Check the tag filter configuration.
3. Look for `failed to read DataType for node` warnings — these nodes are skipped and will not collect data.
4. If the connection itself is failing, look for `failed to create session` and check the OPC UA server address and security settings.

### Pulse authentication errors

1. Set `Timebase.Pulse` to `Debug` in the Pulse `settings.config`.
2. Look for `JWT Authentication Failed` — this means the token presented was invalid.
3. Look for `No signing keys found in storage` — if present, restart Pulse to regenerate the key store.
4. Look for `JWT Token Validated successfully` to confirm a successful validation is occurring for the expected principal.

### Explorer cannot connect to Historian

1. Check Explorer logs for `Explorer Historian[{Index}] 'Host' is not configured` at startup.
2. Look for `Client {name} hub connection to ... has disconnected` to find when the disconnection occurred.
3. Verify the Historian address in the Explorer `settings.config` under the `Historians` section.

- [Software Releases](https://docs.timebase.flow-software.com/knowledge-base/software-releases?hsLang=en)
- [Timebase Quick Start](https://docs.timebase.flow-software.com/knowledge-base/timebase-quick-start?hsLang=en#main-content)

    - [Start Here!](https://docs.timebase.flow-software.com/knowledge-base/timebase-quick-start?hsLang=en#start-here)
    - [System Requirements](https://docs.timebase.flow-software.com/knowledge-base/timebase-quick-start?hsLang=en#system-requirements)
    - [Advanced Topics](https://docs.timebase.flow-software.com/knowledge-base/timebase-quick-start?hsLang=en#advanced-topics)
- [Timebase Historian](https://docs.timebase.flow-software.com/knowledge-base/timebase-historian?hsLang=en)
- [Timebase Data Collectors](https://docs.timebase.flow-software.com/knowledge-base/timebase-data-collectors?hsLang=en)
- [Timebase Explorer](https://docs.timebase.flow-software.com/knowledge-base/timebase-explorer?hsLang=en)
- [Timebase Pulse](https://docs.timebase.flow-software.com/knowledge-base/timebase-pulse?hsLang=en)
- [Windows Services Starter](https://docs.timebase.flow-software.com/knowledge-base/windows-services-starter?hsLang=en)

Copyright © 2025, Flow Software